Type 210 flow sensors The flow sensor type 210 is based on the Karman vortex trail principle. In comparison to the OEM flow sensor (type 200), the type 210 is available with an increased range of power supply and output signals all with and without temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy Key features: Marginal loss of pressure Wide application temperature range Measuring element not sensitive to debris Temperature non-sensitive measuring principle Direct temperature measurement in the medium Flow measuring with voltage, current or frequency output Can be provided with additional internal PT1000 temperature sensor Excellent media resistance (measuring element not in contact with the media) SERIES Type 210 NOMINAL DIAMETER DN 8 MEASURING RANGE (I/m) 0.9 … 15 POWER SUPPLY 8 – 33 VDC OUTPUT (DC) 4 – 20 mA DESCRIPTION Flow sensor CONNECTION G ½ MATERIAL Fibreglass-reinforced plastic MEASURING PRINCIPLE Vortex – Piezoelectric sensor element DRINKING WATER APPROVAL KTW, W270, WRAS ACCURACY At < 50% fs (water) < 1 % fs RESPONSE TIME < 500 ms FLOW MEDIA Heating water with standard additives, potable water (hot/cold) INDEX PROTECTION IP IP65 MEDIUM TEMPERATURE -40... +125 °C ELECTRICAL CONNECTION M12 x 1 (3 pin) (supplied separately)
FLOW SENSOR G 1/2″
Flow sensors & Switches
ElectroMechanica
210.908441K